2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-86/02
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 2.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FAC2/FMGC2 BUS WIRG:
- replace the FAC-2 (1CC2), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the FMGC OWN B bus from the FAC 2 (1CC2) to the first terminal block, (Ref. ASM 22-86/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 232
May 01/04 CESR **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
TASK 22-66-00-810-829
Loss of the Parity Pin Program on the FAC 1
1. Possible Causes
_______________
- FAC-1 (1CC1)
- wiring of the ground signal at the programming pins of the FAC 1 (1CC1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-67/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 1.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS : FAC1/PARITY PIN PRG:
- replace the FAC-1 (1CC1), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the ground signal at the programming pins of the FAC 1 (1CC1), (Ref. ASM 22-67/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 233
201-299, 401-499, Aug 01/05 CES Loss of the Parity Pin Program on the FAC 2
1. Possible Causes
_______________
- FAC-2 (1CC2)
- wiring of the ground signal at the programming pins of the FAC 2 (1CC2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-67/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 2.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS : FAC2/PARITY PIN PRG:
- replace the FAC-2 (1CC2), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the ground signal at the programming pins of the FAC 2 (1CC2), (Ref. ASM 22-67/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 234
201-299, 401-499, Aug 01/05 CES
R **ON A/C ALL
TASK 22-66-00-810-833
中國航空網 www.k6050.com
航空翻譯 www.aviation.cn
本文鏈接地址:A320 Trouble Shooting Manual 排故手冊 AUTO FLIGHT 自動飛行2(10)