CAUTION: DO NOT PUT LARGE CONCENTRATIONS OF THE BIOCIDE IN THE FUEL
_______ TANKS. THE LARGE CONCENTRATIONS CAN MAKE SALT PARTICLES THAT CAN CAUSE CORROSION.
(3)
For the Biocide Kathon FP1.5, add the biocide to the fuel to get a maximum concentration of 100 parts per million (ppm) by weight.
S 652-098
(4)
Refuel the fuel tanks until they are full with fuel that contains the biocide fuel additive.
NOTE: The recommended procedure to put the biocide fuel
____ additive in the fuel is metered injection into a flow of fuel.
S 112-345
(5) To have an effect, let the fuel with the biocide, Biobor JF, stay in the fuel tanks for a minimum of 72 hours.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-11-00
ALL ú ú 01 Page 248 ú May 28/01
A
757
MAINTENANCE MANUAL
S 602-350
(6) To have an effect, let the fuel with the biocide, Kathon FP1.5, stay in the fuel tanks for a minimum of 24 hours.
NOTE: In some cases, more time than 24 hours can be necessary
____
to kill all of the microbial growth.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-11-00
ALL ú ú 01 Page 249 ú May 28/01
A
757
MAINTENANCE MANUAL
FUEL TANKS - INSPECTION/CHECK
_____________________________
1. General
_______
A. This procedure has these tasks:
(1)
Fuel Tank Leak Detection and Repair
中國航空網 www.k6050.com
航空翻譯 www.aviation.cn
本文鏈接地址:757 AMM 飛機維護手冊 燃油 CHAPTER 28 - FUEL 1(58)