29-11-00
ALL ú ú 06 Page 680L ú Jan 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
WARNING: KEEP PERSONS AND EQUIPMENT AWAY FROM ALL CONTROL
_______ SURFACES WHEN YOU SUPPLY THE HYDRAULIC POWER. THE AILERONS, ELEVATORS, RUDDER, FLAPS, SLATS, SPOILERS, AND STABILIZER ARE FULLY POWERED SURFACES. INJURY TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR WHEN YOU SUPPLY THE HYDRAULIC POWER.
2) Put the C HYD PUMPS ELEC 1 pump switch to the ON position.
(b) If you use the hydraulic service cart, do these steps:
1) Connect the service cart pressure and return lines to the center system ground power connections with a flowmeter installed in the cart pressure line.
WARNING: KEEP PERSONS AND EQUIPMENT AWAY FROM ALL CONTROL
_______ SURFACES WHEN YOU SUPPLY THE HYDRAULIC POWER. THE AILERONS, ELEVATORS, RUDDER, FLAPS, SLATS, SPOILERS, AND STABILIZER ARE FULLY POWERED SURFACES. INJURY TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR WHEN YOU SUPPLY THE HYDRAULIC POWER.
2) Operate the hydraulic service cart to pressurize the center system to 3000 psi.
S 486-334
(2) If you use the multimeter technique, do these steps:
(a) Do these steps to install the multimeter and the clamp-on ac current probe: 1) Get access to the center system ACMP C1 ELCU M10006 in the
中國航空網 www.k6050.com
航空翻譯 www.aviation.cn
本文鏈接地址:757 AMM 飛機維護手冊 液壓 CHAPTER 29 - HYDRAULIC POWER 1(153)