Enunciation: “PROGRAM PIN PARITY ERROR” (MK V or MK VII only)
Probable Cause: Wiring error in the program pins.
Action: Verify wiring to each program pin. Verify ODD parity selected.
Enunciation: “AIRCRAFT TYPE INVALID” (MK V or MK VII only)
Probable Cause: Wiring error to the Aircraft Type program pins.
Action: Verify wiring to the Aircraft Type program pins.
Enunciation: “CONFIGURATION TYPE INVALID” (MK VI or MK VIII only)
Probable Cause: The programmed configuration type is not a valid configuration.
Action: Correct and reprogram the Configuration Module (see Maintenance Practices section)
Enunciation: “AIRCRAFT CONFIGURATION DATA BASE FAILED” (MK V or MK VII only)
Probable Cause: EGPWC internal Configuration database error.
Action: Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing or replacing the EGPWC for repair (see Removal/Installation section)
Enunciation: “ APPLICATION DATA BASE FAILED” (MK VI or MK VIII only)
Probable Cause: EGPWC internal Application database error.
Action: Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing or replacing the EGPWC for repair (see Removal/Installation section)
Enunciation: “AIRCRAFT CONFIGURATION DATA BASE CRC FAILED” (MK V or MK VII only)
Probable Cause: EGPWC internal configuration database error.
Action: Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing or replacing the EGPWC for repair (see Removal/Installation section)
Enunciation: “ APPLICATION DATA BASE CRC FAILED” (MK VI or MK VIII only)
Probable Cause: EGPWC internal Application database error.
Action: Pull power to the EGPWS for one minute and cycle power to clear all potential faults before removing or replacing the EGPWC for repair (see Removal/Installation section)
Enunciation: “CONFIGURATION MODULE READ ERROR” (MK VI or MK VIII only)
Probable Cause: The Configuration Module is faulty.
Action: Verify Configuration Module connections. Cycle power to the EGPWC. If the problem persists, reprogram the Configuration Module. IF the condition persist, replace the Configuration Module. See Removal/Installation section.
POSSIBLE SELF-TEST PREAMBLE RESULTS
Enunciation: “CONFIGURATION MODULE NOT PROGRAMMED” (MK VI or MK VIII only)
Probable Cause: The Configuration Module is not programmed.