PASSENGER OXYGEN SYSTEM
CREW OXYGEN SYSTEM
LEGEND
CHEMICAL OXYGEN GENERATORO G
2(IN EACH SERVICE UNIT)CREW STATION WITH MASK STORAGE BOX (EXAMPLE)
CREW STATION WITH NO MASK STORAGE BOX (EXAMPLE)
Oxygen System Block Diagram
Figure 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-00-00
ALL ú
ú 01 Page 2
ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
OXYGEN SYSTEMS - MAINTENANCE PRACTICES
______________________________________
1. General_______
A. This procedure has one task which is the oxygen system general maintenance practices. This task contains the safety precautions, general maintenance data, and oxygen systems maintenance practices for the crew oxygen system.
B. Read and follow this procedure before you do maintenance on the crew oxygen system.
TASK 35-00-00-912-001
2. Oxygen System General Maintenance Practices___________________________________________
A. Consumable Materials
(1)
G00091 Compound - Leak Detection for the Oxygen System MIL-L-25567
(2)
Tape, Pipe Thread Sealing - 1/4 inch wide (Ref 20-30-51/201)
B. References
(1)
20-40-11/201, Static Grounding
(2)
20-50-11/201, Standard Torque Values
(3)
24-22-00/201, Manual Control
(4)
35-00-00/701, Oxygen Systems
C. Procedure - Safety Precautions
S 912-002
WARNING: DO NOT WORK ON THE PRESSURIZED OXYGEN SYSTEM WHEN THERE IS OIL,
_______ GREASE, FLAMMABLE SOLVENTS, DUST, LINT, METAL PARTICLES, OR OTHER FLAMMABLE MATERIALS. THESE MATERIALS CAN CAUSE A FIRE OR EXPLOSION WHEN THEY TOUCH PRESSURIZED OXYGEN.
(1)
Do not work on the pressurized oxygen near oil, grease, flammable solvents, dust, lint, metal fittings, or other flammable materials.
S 912-003
(2)
Make sure the airplane is electrically grounded (Ref 20-40-11/201).
中國航空網(wǎng) www.k6050.com
航空翻譯 www.aviation.cn
本文鏈接地址:737-300 400 500 AMM 飛機維護手冊 氧氣 OXYGEN(2)