NOTE 1 : If a 100-hr. inspection has been carried out during the last 3 months, do not perform the operations identified with a "0" unless the annual inspection replaces a 100-hr. inspection. For US registered aircraft, perform all operations.
ATA OPERATIONS INSPECTIONS
Area 1st
25 hrs 50
hrs 100
hrs Major Ann. Other
28-40 3) Remove the R.H. tank float gages (if
installed). 600 X
Check the floats for porosity and travel,
check the tracks and the seal for condition.
Install the float gages - refer to
28-40-01 401.
28-40 4) Remove the R.H. tank capacitor gages (if installed). 600 X
Check the sensors for condition, check the transmitter for corrosion or deposits, check the connections for security.
Replace the 0-ring seal.
Install the capacitor gages - refer to