曝光臺 注意防騙
網(wǎng)曝天貓店富美金盛家居專營店坑蒙拐騙欺詐消費者
L1Crew awareness.
STATUS
INOP SYS
HF 1(2) DATA
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
ELECTRICAL
A318/A319/A320/A321 FLEET PRO-ABN-24 P 1/252
FCOM 19 AUG 10
ELEC IDG 1(2) OIL LO PR/OVHT
Applicable to:
IDG (AFFECTED)........................................................................................................................OFF
L2 If the associated engine is running, the IDG (integrated drive generator) must be disconnected from
the engine at, or above, idle to prevent damage to the disconnect mechanism.
Press the IDG until the GEN FAULT comes on. However, do not press for more than 3 s, to avoid
damage to the disengage solenoid
The IDG FAULT goes off, when the IDG is disconnected.
L12
STATUS
Note: If available, the APU may be started and the APU GEN
used.
CAT 3 SINGLE ONLY
INOP SYS
MAIN GALLEY (1)
GEN 1(2)
CAT 3 DUAL
(1) (only if APU GEN is not online)
ELEC IDG 1(2) OIL LO PR/OVHT
Applicable to:
MSN,
IDG (AFFECTED)........................................................................................................................OFF
L2 If the associated engine is running, the IDG (integrated drive generator) must be disconnected from
the engine at, or above, idle to prevent damage to the disconnect mechanism.
Press the IDG until the GEN FAULT comes on. However, do not press for more than 3 s, to avoid
damage to the disengage solenoid
The IDG FAULT goes off, when the IDG is disconnected.
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
ELECTRICAL
A318/A319/A320/A321 FLEET PRO-ABN-24 P 2/252
FCOM 19 AUG 10
ELEC IDG 1(2) OIL LO PR/OVHT (Cont'd)
L12
STATUS
Note: If available, the APU may be started and the APU GEN
used.
CAT 3 SINGLE ONLY
INOP SYS
MAIN GALLEY (1)
GEN 1(2)
CAT 3 DUAL
(1) (only if APU GEN is not online)
ELEC IDG 1(2) OIL LO PR/OVHT
Applicable to: ,
IDG (AFFECTED)........................................................................................................................OFF
L2 If the associated engine is running, the IDG (integrated drive generator) must be disconnected from
the engine at, or above, idle to prevent damage to the disconnect mechanism.
Press the IDG until the GEN FAULT comes on. However, do not press for more than 3 s, to avoid
damage to the disengage solenoid
The IDG FAULT goes off, when the IDG is disconnected.
L12
STATUS
Note: If available, the APU may be started and the APU GEN
used.
CAT 3 SINGLE ONLY
INOP SYS
MAIN GALLEY (1)
GEN 1(2)
CAT 3 DUAL
(1) (only if APU GEN is not online: In this case, all the galleys are shed)
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
ELECTRICAL
A318/A319/A320/A321 FLEET PRO-ABN-24 P 3/252
FCOM 19 AUG 10
ELEC IDG 1(2) OIL LO PR/OVHT
Applicable to: , MSN,,
IDG (AFFECTED)........................................................................................................................OFF
L2 If the associated engine is running, the IDG (integrated drive generator) must be disconnected from
the engine at, or above, idle to prevent damage to the disconnect mechanism.
Press the IDG until the GEN FAULT comes on. However, do not press for more than 3 s, to avoid
damage to the disengage solenoid
The IDG FAULT goes off, when the IDG is disconnected.
L12
STATUS
Note: If available, the APU may be started and the APU GEN
used.
CAT 3 SINGLE ONLY
INOP SYS
MAIN GALLEY (1)
GEN 1(2)
CAT 3 DUAL
(1) (only if APU GEN is not online: In this case, all the galleys are shed)
ELEC GEN 1(2) FAULT
Applicable to:
GEN (AFFECTED).......................................................................................................OFF THEN ON
IF UNSUCCESSFUL:
GEN (AFFECTED)..................................................................................................................OFF
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
ELECTRICAL
A318/A319/A320/A321 FLEET PRO-ABN-24 P 4/252
FCOM 19 AUG 10
ELEC GEN 1(2) FAULT (Cont'd)
L12
STATUS
Note: If available, the APU may be started, and the APU GEN
used.
CAT 3 SINGLE ONLY
INOP SYS
MAIN GALLEY (1)
GEN 1(2)
CAT 3 DUAL
(1) (only if APU GEN is not online)
中國航空網(wǎng) www.k6050.com
航空翻譯 www.aviation.cn
本文鏈接地址:
A320機組操作手冊FLIGHT CREW OPERATING MANUAL 8(110)