**ON A/C 001-049, 051-099, 101-149, 201-299, 27-41-44-991-002 Fig. 402 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R **ON A/C 151-199, 401-499,
27-41-44-991-002-A Fig. 402A
**ON A/C 301-399,
27-41-44-991-002-B Fig. 402B
**ON A/C ALL
27-41-44-991-008 Fig. 403
27-41-44-991-003 Fig. 404
27-41-44-991-004 Fig. 405
27-41-44-991-005 Fig. 406
27-41-44-991-006 Fig. 407
27-41-44-991-007 Fig. 408
3. Job Set-up
__________
**ON A/C 001-049, 051-099, 101-149, 201-299,
(Ref. Fig. 401/TASK 27-41-44-991-001) R **ON A/C 151-199, 401-499,
(Ref. Fig. 401A/TASK 27-41-44-991-001-A)
**ON A/C 301-399,
(Ref. Fig. 401B/TASK 27-41-44-991-001-B)
Location of Access
Figure 401/TASK 27-41-44-991-001
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 27-41-44Page 404 1 1 May 01/05 1 1 1CES 1
Location of Access
Figure 401A/TASK 27-41-44-991-001-A
R 1EFF : 151-199, 401-499, 1 27-41-44Page 405 1 1 Aug 01/05 1 1 1CES 1
R Location of Access
R Figure 401B/TASK 27-41-44-991-001-B
R 1EFF : 301-399, 1 27-41-44 Page 406
1 1 May 01/04
1 1
1CES 1
**ON A/C 001-003, 051-053,
Subtask 27-41-44-010-050
A. Get Access
(1)
Put the access platform in position at the zone 121.
(2)
Put the access platform in position at the zone 132.
(3)
Put the access platform in position at the zone 154.
(4)
Put the access platform in position at the zone 312.
(5)
Open the access doors 811, 825, 826, 312AR.
(6)
In the zones 211 and 221, remove the floor panels 211GF, 211KF, 221AF, 221EF, 231CF (Ref. TASK 53-12-11-000-001) (Ref. TASK 53-12-12-000-001).
(7)
In the zone 241, remove the floor panels 231WF, 241BF, 241FF, 241KF (Ref. TASK 53-22-12-000-001) (Ref. TASK 53-32-12-000-002).
(8)
In the zone 131, remove the ceiling panels 131AC, 131BC, 131CC, 131PW (Ref. TASK 25-54-12-000-002).
(9)
In the zones 151 and 161, remove the ceiling panels 151AC, 151BC, 151CC, 151DC, 161AC, 161BC (Ref. TASK 25-55-11-000-002) (Ref. TASK 25-55-12-000-002).
R **ON A/C 151-199, 401-499,
Subtask 27-41-44-010-050-E
A. Get Access
(1)
Put the access platform in position at the zone 121.
(2)
Put the access platform in position at the zone 132.
(3)
Put the access platform in position at the zone 154.
(4)
Put the access platform in position at the zone 312.
(5)
Open the access doors 811, 825, 826, 312AR.
R 1EFF : 001-003, 051-053, 151-199, 401-499, 1 27-41-44Page 407 1 1 Aug 01/05 1 1 1CES 1
(6)
In the zones 211, 221 and 231, remove the floor panels 211GF, 211KF, 221EF, 231CF 221LF (Ref. TASK 53-12-11-000-001) (Ref. TASK 53-12-12-000-001).
(7)
In the zones 231 and 241, remove the floor panels 231WF, 241BF, 241FF, 241KF (Ref. TASK 53-22-12-000-001) (Ref. TASK 53-32-12-000-002).
(8)
In the zone 131, remove the ceiling panels 131KC, 131MC, 131NC, 131PW (Ref. TASK 25-54-12-000-002).
(9)
In the zones 151 and 161, remove the ceiling panels 151EC, 151FC, 151GC, 161AC, 161BC (Ref. TASK 25-55-11-000-002) (Ref. TASK 25-55-12-000-002).
**ON A/C 301-399,
Subtask 27-41-44-010-050-D
A. Get Access
(1)
Put the access platform in position at the zone 121.
(2)
Put the access platform in position at the zone 132.
(3)
Put the access platform in position at the zone 154.
(4)
Put the access platform in position at the zone 312.
(5)
Open the access doors 811, 825, 826, 312AR.
(6)
In the zones 211 and 221, remove the floor panels 211GF, 211KF, 221EF, 231CF 221LF (Ref. TASK 53-12-11-000-001) (Ref. TASK 53-12-12-000-001).
(7)
In the zone 241, remove the floor panels 231WF, 241BF, 241FF, 241KF (Ref. TASK 53-22-12-000-001) (Ref. TASK 53-32-12-000-002).
(8)
In the zone 131, remove the ceiling panels 131AC, 131BC, 131CC, 131DC, 131EC, 131PW (Ref. TASK 25-54-12-000-002).