GULFSTREAM AEROSPACE CORPORATION PAGE NUMBER: 26-3
AIRCRAFT: GULFSTREAM AEROSPACE MODEL G-IV MMEL REVISION NO.: 5 MOP REV. NO.: 5
MAINTENANCE / OPERATIONAL / PLACARDING / PROCEDURES MANUAL MMEL DATE: 10/11/01 MOP DATE: 10/11/01
1. 2. NUMBER INSTALLED
SYSTEM & 5. MAINTENANCE 6. OPERATIONAL 7. PLACARDING
SEQUENCE 3. NUMBER REQ’D FOR DISPATCH PROCEDURES PROCEDURES PROCEDURES
NUMBERS 4. MMEL REMARKS OR
EXCEPTIONS
26. FIRE PROTECTION
5. Lavatory Smoke C
*** Detection System
(M) (O) For each lavatory, the lavatory
smoke detection system may be inoperative
provided:
a) Lavatory waste receptacle is
empty,
b) Lavatory door is locked
CLOSED and placarded,
“INOPERATIVE – DO NOT
ENTER”, and
c) Lavatory is not used for any
purpose.
Maintenance will ensure
Lavatory Smoke Detector CB is
pulled and ty-wrapped.
Flight crew will inspect
lavatory to ensure Lavatory
Waste Receptacle is empty
and Lavatory Door is
LOCKED CLOSED. In
addition, flight crew will
ensure Lavatory is NOT used
for any purpose.
An Inoperative Placard will
be placed on Lavatory Door
stating "Inoperative - Do
Not Enter" and will be noted
on ADLS.
NOTE 1: These provisos are not intended
to prohibit lavatory inspections by
crewmembers.
NOTE 2: Lavatory smoke detection system
is not required for all-cargo operations.
6. Lavatory Fire C
*** Extinguisher
Systems
For each lavatory, the lavatory fire
extinguisher system may be inoperative
provided Lavatory Smoke Detector system
operates normally.
None required. None required. An Inoperative Placard will
be placed on Lavatory Door
stating "Inoperative - Do
Not Enter" and will be noted
on ADLS.
26-4
GULFSTREAM AEROSPACE CORPORATION PAGE NUMBER: 26-4
AIRCRAFT: GULFSTREAM AEROSPACE MODEL G-IV MMEL REVISION NO.: 5 MOP REV. NO.: 5
MAINTENANCE / OPERATIONAL / PLACARDING / PROCEDURES MANUAL MMEL DATE: 10/11/01 MOP DATE: 10/11/01
1. 2. NUMBER INSTALLED
SYSTEM & 5. MAINTENANCE 6. OPERATIONAL 7. PLACARDING
SEQUENCE 3. NUMBER REQ’D FOR DISPATCH PROCEDURES PROCEDURES PROCEDURES
NUMBERS 4. MMEL REMARKS OR
EXCEPTIONS
26. FIRE PROTECTION
6. Lavatory Fire Extinguisher
*** Extinguisher Systems
(cont’d)
(M) (O) For each lavatory, the lavatory fire
extinguisher system may be inoperative
provided:
a) Lavatory waste receptacle is
empty,
b) Lavatory door is locked
CLOSED and placarded,
“INOPERATIVE – DO NOT
ENTER”, and
c) Lavatory is not used for any
purpose.
Maintenance will:
a) Verify Lavatory Smoke
Detector is operative.
Utilize Vendor
Maintenance Manual to
verify operation.
b) Verify Lavatory Waste
Receptacle is empty.
Flight crew will inspect
lavatory to ensure Lavatory
Waste Receptacle is empty
and Lavatory Door is
LOCKED CLOSED. In
addition, flight crew will
ensure Lavatory is NOT used
for any purpose.
An Inoperative Placard will
be placed on Lavatory Door
stating "Inoperative - Do
Not Enter" will be noted on
ADLS.
NOTE 1: These provisos are not intended
to prohibit lavatory inspections by
crewmembers.
NOTE 2: A lavatory fire extinguisher
system is not required for all-cargo
operations.
7. Galley Smoke D
*** Detection Systems
0 None required. None required. An Inoperative Placard will
be placed on Galley Curtain
and will be noted on ADLS.
8. Galley Fire D
*** Extinguishing
Systems
0 None required. None required.
26-5
GULFSTREAM AEROSPACE CORPORATION PAGE NUMBER: 26-5
AIRCRAFT: GULFSTREAM AEROSPACE MODEL G-IV MMEL REVISION NO.: 5 MOP REV. NO.: 5
MAINTENANCE / OPERATIONAL / PLACARDING / PROCEDURES MANUAL MMEL DATE: 10/11/01 MOP DATE: 10/11/01
1. 2. NUMBER INSTALLED
SYSTEM & 5. MAINTENANCE 6. OPERATIONAL 7. PLACARDING
SEQUENCE 3. NUMBER REQ’D FOR DISPATCH PROCEDURES PROCEDURES PROCEDURES
NUMBERS 4. MMEL REMARKS OR
EXCEPTIONS
26. FIRE PROTECTION
8. Galley Fire D
*** Extinguishing
Systems
0 None required. None required. An Inoperative Placard will
be placed on Galley Curtain
and will be noted on ADLS.
9. Engine Fire C
Detection Systems
2 1 One complete loop (A or B) may be
inoperative provided the Fault Switch/Light
is pressed to isolate the faulty loop and
中國航空網 www.k6050.com
航空翻譯 www.aviation.cn
本文鏈接地址:
灣流4維護/操作/標牌程序手冊MOPPM GULFSTREAM IV MAINTENANCE/O(35)