3. Job Set-up
__________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 27-94-00-860-055
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(2)
Make sure that the aircraft hydraulic systems are depressurized (Ref. TASK 29-23-00-864-001) (Ref. TASK 29-24-00-864-001) (Ref. TASK 29-10-00-864-003).
(3)
On the FLT CTL panel 23VU:
-make sure that the FLT CTL/SEC 1 and FLT CTL/ELAC 1 pushbutton switches are pushed (on these pushbutton switches, the FAULT and OFF legends are off)
-release the FLT CTL/SEC 1 pushbutton switch (on this pushbutton switch the OFF legend comes on).
(4)
On the FLT CTL panel 24VU:
-make sure that the FLT CTL/SEC 2, FLT CTL/SEC 3 and FLT CTL/ELAC 2 pushbutton switches are pushed (on these pushbutton switches, the FAULT and OFF legends are off)
-release the FLT CTL/SEC 3 pushbutton switch (on this pushbutton switch the OFF legend comes on).
(5)
Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
(6)
On the center pedestal, on the ECAM control panel, push the F/CTL key (on the lower ECAM DU, the F/CTL page comes into view).
(7)
On the panel 114VU, make sure that the flap and slat control lever is not in position FULL.
(8)
Read the status of the monitored circuit breakers (installed on the battery power center 105VU), directly on the upper ECAM DU. If the warning C/B TRIPPED R ELEC BAY is shown, get access to 105VU panel:
(a)
Put the access platform in position at the access door 822.
(b)
Open the access door 822.
(c) On the battery power center 105VU, loosen the two screws and
remove the protective cover.
R **ON A/C 301-399,
R Subtask 27-94-00-860-055-A
R A. Aircraft Maintenance Configuration
R (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-
R 002).
R (2) Make sure that the aircraft hydraulic systems are depressurized
R (Ref. TASK 29-23-00-864-001) (Ref. TASK 29-24-00-864-001) (Ref. TASK
R 29-10-00-864-003).
R (3) On the FLT CTL panel 23VU:
R - make sure that the FLT CTL/SEC 1 and FLT CTL/ELAC 1 pushbutton
R switches are pushed (on these pushbutton switches, the FAULT and
R OFF legends are off)
R - release the FLT CTL/SEC 1 pushbutton switch (on this pushbutton
R switch the OFF legend comes on).
R (4) On the FLT CTL panel 24VU:
R - make sure that the FLT CTL/SEC 2, FLT CTL/SEC 3 and FLT CTL/ELAC 2
R pushbutton switches are pushed (on these pushbutton switches, the
R FAULT and OFF legends are off)
R - release the FLT CTL/SEC 3 pushbutton switch (on this pushbutton
R switch the OFF legend comes on).
R (5) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
R (Ref. TASK 31-60-00-860-001).
R (6) On the center pedestal, on the ECAM control panel, push the F/CTL key
R (on the lower ECAM DU, the F/CTL page comes into view).
R (7) On the panel 114VU, make sure that the flap and slat control lever is
R not in position 3 or FULL.
R (8) Read the status of the monitored circuit breakers (installed on the
中國航空網 www.k6050.com
航空翻譯 www.aviation.cn
本文鏈接地址:A320飛機維護手冊 AMM FLIGHT CONTROLS 飛行操縱9(94)